Replacement Voice Coil for Scan-speak tweeters

  • D2905/9300 
  • D2905/9500 
  • D2905/9700
General Instructions for Repair:

1. Remove the four small Torx screws (T8 bit) that hold the tweeter faceplate to the magnet assembly. Set aside.
2. Remove the plastic ring. Set aside.
3. Carefully remove the foam gasket. Set aside.
4. Clip voice coil lead wires from solder tabs.
5. Remove solder tabs. Discard.
6. Remove voice coil assembly from magnet assembly. You may have to pry it out. Discard.
7. Remove tape on new voice coil assembly.
8. Fully insert new voice coil assembly into magnet assembly. Make sure to line up the voice coil lead wires with solder tab location.
9. Insert new solder tabs.
10. Solder voice coil lead wires to solder tabs.
11. Replace foam gasket.
12. Replace plastic ring.
13. Replace face plate.
14. Slowly tighten four Torx screws.


 